OM4035.2 02/03 Maintenance - Section 4 Automatic Lube System Page 4- 17 Pressure Failure Detection Circuits 4. Once RB6-K6 is energized, it will latch and remain latched as long as the key switch in ON. Also, RB6-K2 will remain energized and the Low Lube Pressure Warning light will remain on to notify the operator a problem exists and the system requires service. 1. When the lubrication cycle is initiated, 24VDC flows through relay RB6-K4 (8, Figure 3-4) N.C. contacts to a 1 minute delay timer (7). 2.
If the system is operating normally, grease pres- sure at the rear axle injector bank will rise to pres- sure switch (9) setting of 2000 psi (13.8 MPa), closing the switch contacts and energizing relay RB6-K4 (8), removing 24 volts from the delay timer. The timer is then reset and no current will flow from the timer output terminal. 5. The warning circuits are reset when the key switch is turned OFF. 3. If a problem occurs and the system is not able to attain 2000 psi (13.8 MPa), then delay timer (7) will energize relay RB6-K2 after 60 seconds, turn- ing on the “Low Lube System Pressure” warning lamp on the overhead display.
After RB6-K2 energizes, it will ground the coil of RB6-K6 and allow it to energize. 1. Solid State Timer 2. Circuit Breaker 33 (Power Distribution Module in Cab) 3. Circuit Breaker 35 (Power Distribution Module in Cab) 4. Pressure Switch (On Grease Pump) 5. Pump Solenoid Valve 6. Relay Board 6, Relay K6 FIGURE 3-4. ELECTRICAL SCHEMATIC 7. Time Delay Module 8. Relay Board 6, Relay K4 9. Pressure Switch (rear Axle Injector Bank) 10.Relay Board 6, Relay K2 11.Auto Lube Low Pressure Warning Lamp 12.Relay Board 6, relay K1 13.Manual Override