Hyundai Construction Equipment — 3. ELECTRICAL SYSTEM

210S6ES62 4 3 H 2 F 6-36 6-36 Repair or replace (After clean) Charge or replace (After clean) 余 Before disconnecting the connector, always turn the starting switch OFF. 余 Before carrying out below procedure, check all the related connectors are properly inserted and master switch ON 余 After checking, insert the disconnected connectors again immediately unless otherwise specified.

Cause Remedy Replace Replace Replace Disconnection in wiring harness or poor contact between CS-2 (1)- CN-8 (12)-CS-74B- Fuse No.1 - CS-74A-CN-60- CR-1-Battery Disconnection in wiring harness or poor contact between DO-2 (2)- CR-1 or defective battery relay Disconnection in wiring harness or poor contact between CS-2 (2)- CN-8 (11)- DO-2 (1) Defective start key switch Battery capacity too low 13. WHEN STARTING SWITCH “ON” ELECTRIC PART DOES NOT OPERATE YES NO Check voltage between DO-2 (1) and chassis Voltage : 20~30V YES NO Check voltage between CS-2 (2) and chassis Voltage : 20~30V YES NO Check voltage between CS-2 (1) and chassis Voltage : 20~30V YES Specific gravity : MIN 1.28 Voltage :

MIN 24V NO Check voltage and specific gravity of battery YES YES Check voltage between DO-2 (1) and chassis Voltage : 20~30V YES Check voltage between CS-2 NO (2) and chassis Voltage : 20~30V Check voltage YES between CS-2 (1) and chassis Voltage : 20~30V NO NO Check voltage and specific gravity of battery Specific gravity : MIN 1.28 Voltage : MIN 24V NO Cause Disconnection in wiring harness or Remedy Repair or replace (After clean) Check voltage between DO-2 (1) and chassis Voltage :

20~30V NO NO poor contact between DO-2 (2)- CR-1 or defective battery relay Disconnection in wiring harness or poor contact between CS-2 (2)- CN-8 (11)- DO-2 (1) Defective start key switch Disconnection in wiring harness or poor contact between CS-2 (1)- CN-8 (12)-CS-74B- Fuse No.1 - CS-74A-CN-60- CR-1-Battery Battery capacity Replace Replace Replace Charge or replace 6-36 6-36