7. MALFUNCTION OF WARMING UP 侍 Before carrying out below procedure, check all the related connectors are properly inserted. 1) INSPECTION PROCEDURE Wiring diagram MCU WATER TEMPERATURE SENDER GND (SENSOR) 31 11 WATER TEMP SENSOR 33 12 CD-8 CN-51 CN-2 210S6ES53 6-54 YES Check resistance YES between CN-51 (33) - CD-8 (2) SPEC : Below10 凂 NO ck resistance Starting switch OFF een CN -51 - CD-8 (1) : Below 10 凂 g switch OFF NO Cause Remedy Defective cluster or MCU or CD-8 Poor connection between CN-51 (33) - CD-8 (2) Poor connection between CN-51 (31) - CD-8 (1) Repair or Replace Repair Repair 1 2 oC