10) OPERATION OF NEGATIVE CONTROL VALVE When no function is being actuated on P1 side, the hydraulic fluid from the P2 port, flows into the tank passage through the P1 bypass passage and the orifice of the negative control valve. The negative control pressure caused by this operation is transferred to the regulator of the piston pump through the Pn1 port. This pressure controls the swash plate angle of the pump to the minimum and minimize the flow of the P1 side. When one or more spools are shifted, the P1 bypass passage is shut-off and the flow is almost zero.
Accordingly, the negative control pressure that is supplied to the pump through Pn1 port is lowered and the swash plate angle becomes maximum and the flow of the P1 side becomes maximum. On the other hand, the negative control pressure is increased and high than the setting pressure of the spring, the negative control valve is opened and the flow passes to the hydraulic tank and functions as a relief valve. The operation of the negative control valve of the P2 side is same as that of the P1 side.
Pn2 port Adjust swash plate angle of pump Pn1 port P2 negative control valve Spring P1 negative control valve Tank passage P1 parallel passage OPERATION OF NEGATIVE CONTROL VALVE 220S2MC37 2-51 alve by orifice pressure P O Z Z S Z Z Z Z Z Z