Option flow summation function, bypass cut-off 2 spool During the 2-way option operation, the pilot secondary pressure from the RCV is supplied to port of the spring side and shifts the BC2 (option) spool. The P1 parallel passage is shut off by the movement of the BC2 spool and the pressurized oil from P1 port opens the check poppet and combined with flow of the option spool.
(Only bucket in operation) Bucket RCV signal RCV signal Bucket flow summation passage Option Open check poppet and combined with oil flow of bucket spool F-F' (OPTION AND BUCKET) P1 parallel passage Z Z SECTION Z-Z Option spool RCV signal (when left and right shift) Z Z BC2 spool (option) G-G' (BYPASS CUT & NEGATIVE CONTROL) FLOW SUMMATION BY THE SHIFTING OF THE BC2 SPOOL 220S2MC36 2-50