Komatsu — CHECKS BEFORE STARTING

OPERATION 5. If the oil is above the (H) mark on the gauge, remove cover (1), drain the excess oil from drain valve (P) at the bottom of the engine oil pan, then check the oil level again. 6. If oil level is correct, securely tighten the oil filler cap and close the engine hood. Remark When checking the oil level after the engine has been operated, wait for at least 15 minutes after stopping the engine before checking. If the machine is at an angle, make it horizontal before checking. CHECK ELECTRICAL WIRING If fuses are frequently blown or if there are traces of short-circulating in the electrical wiring, contact your Komatsu distributor to locate the cause and make the repair.

Keep the top surface of the battery clean and check the vent hole in the battery cap. If it is clogged with dirt or dust, wash the battery cap to clear the vent hole. Check for loosened terminals. If found, tighten them. Pay particular attention to the electric wiring when checking the battery, engine starting motor and alternator. Be sure to check to be sure there is no flammable material accumulated around the bat- tery. If any is found, remove immediately. CHECK OR ADD FUEL When adding fuel, never spill the fuel or let it overflow. If any fuel has spilled, wipe it up immediately. If fuel has spilled over soil or sand, remove that soil or sand. Fuel is highly flammable and dangerous.

Never bring flames near fuel. 1. Turn the engine ignition switch to the ON position and check the fuel level gauge (1) on the monitor panel for fuel level. After checking, turn the switch back to the OFF position. 2. If fuel is found to be low, unscrew fuel filler cap (F) on the fuel tank and add fuel through the filler port until float gauge (G) comes up to the highest point. Fuel tank capacity: . . . . . . . . . . . . . .650 liters (173.73 US gal) Position of tip (a) of float gauge (G) when fuel tank is full: 50 mm (2 in) 3. After adding fuel, push float gauge (G) straight down with fuel filler cap (F). 2-74 PC400LC-7E0