OPERATION 1. This machine is equipped with an automatic engine warming-up system, so if the engine water temperature is below 30 o C (86 o F) after the engine is started, the engine warming-up operation starts automatically. When the engine automatic warming-up operation starts, the engine speed is maintained at a speed higher than the normal low idling speed. If the engine water temperature goes above 30 o C (86 o F) or if the warming-up operation has been continued for more than 10 minutes, the automatic warming-up operation is cancelled and the engine speed drops to the normal low idling speed. 2. Check to be sure engine water temperature monitor (1) displays green.
If it displays white, use the procedure in Step 3 to carry out additional warming up of the engine until the monitor displays green. 3. Turn fuel control dial (2) to a point midway between low idling (MIN) and full speed (MAX), run the engine at a mid-range speed, and run under no load until engine water temperature monitor (1) displays green. If the engine water temperature monitor displays green, the engine warming-up operation is completed. After checking that the engine water temperature monitor displays green, carry out the warming-up operation for the hydraulic equipment.
CANCELING AUTOMATIC WARMING-UP OPERATION If it becomes necessary in an emergency to cancel the automatic warming-up operation or to lower the engine speed to low idle, do as follows. 1. Turn fuel control dial (2) to the full speed (MAX) position and hold it for 3 seconds. 2. When fuel control dial (2) is returned to the low idle (MIN) posi- tion, the engine speed will drop. 2-86 PC400LC-7E0