Komatsu — CLEAN INSIDE OF COOLING SYSTEM

MAINTENANCE 2. Be sure the cooling system and coolant are cold, do not run the engine to warm the coolant. 3. Remove cover (2). 4. Once the engine is cold remove the radiator cap (3) to prepare the system for draining. Remark Always drain the coolant when the engine and coolant is cold. 5. Remove drain valve cover (4) at the bottom of the radiator side and drain valve cover (5) on the engine side and drain the coolant. 6. Set containers to catch coolant for recycling and open valve (6) and (7) to drain the old coolant. 7. After draining the antifreeze solution flush system with clean water then close drain valve (6) and (7), then fill with clean water.

After the radiator is filled with water, start and run the engine at low idle speed. After the water temperature rises above 90 o C (194 o F), run the engine for about 10 minutes. 8. Stop the engine and allow the engine to cool down completely. Open drain valve (6) and (7) to drain the water. 9. After draining the water, flush the cooling system again using a flushing agent (Restore or Restore Plus by Fleet guard). PC400LC-7E0 3-27