Komatsu — CHECKING CHARGE PRESSURE IN ACCUMULATOR (FOR CONTROL CIRCUIT)

MAINTENANCE EVERY 4000 HOURS MAINTENANCE Maintenance for every 250, 500, 1000 and 2000 hours service should be performed at the same time. CHECK WATER PUMP Since the pulley may have play, oil may leak, water may leak and the drain hole (A) may be clogged, contact your Komatsu distributor for inspection, overhaul or replacement. CHECKING CHARGE PRESSURE IN ACCUMULATOR (FOR CONTROL CIRCUIT) Replace the accumulator every 2 years or every 4000 hours, which ever comes first. The accumulator is charged with high-pressure nitrogen gas, so mistaken operation may cause an explosion, which will lead to serious injury or damage. When handling the accumulator, always do as follows:

The pressure in the hydraulic circuit cannot be completely removed. When removing the hydraulic equipment, do not stand in the direction that the oil spurts out when carrying out the operation. In addition, loosen the bolts slowly when carrying out the operation. Do not disassemble the accumulator. Do not bring it near flame or dispose of it in fire. Do not make holes in it or weld it. Do not hit it, roll it, or subject it to any impact. When disposing of the accumulator, the gas must be released. Please contact your Komatsu distribu- tor to have this work carried out.

Remark If the nitrogen gas charge pressure in the accumulator is low and operations are continued, it will become impossible to release the remaining pressure inside the hydraulic circuit if a failure occurs on the machine. Please ask your Komatsu distributor to replace the accumulator. The accumulator is installed to the position shown in the diagram on the right. PC400LC-7E0 3-73