OPTIONS, ATTACHMENTS ATTACHMENT INSTALLATION AND REMOVAL PROCEDURE REMOVAL PROCEDURE 1. Place the attachment on the ground and stop the engine. 2. Turn the starting switch to the ON position and pull up the safety lock lever to FREE position. 3. Operate each work equipment control lever and the attachment control pedal back and forth, left and right at full stroke two to three times to eliminate the internal pressure in the hydraulic circuit. 4. Loosen slowly oil filler cap (F) on top of the hydraulic tank to eliminate the internal pressure in the hydraulic circuit. 5.
After confirming low oil temperature, turn the rotor of the stop valve connected to the inlet and outlet piping on the arm side face toward the lock side (L). 6. Remove the hoses on the attachment side. Install the blind plugs to the two outlets. The blind plugs are used to prevent the attachment from incorrect operation caused by mixing of foreign matter. After the plugs are correctly installed, store the attachment. 5-14 PC400LC-7E0