OPTIONS, ATTACHMENTS 7. Remove the attachment by removing the retaining pins (2 pins). Then, mount the bucket. 8. After the bucket is mounted, check the hydraulic oil level. INSTALLATION PROCEDURE 1. Remove the bucket. 2. Place the attachment in a horizontal position, then install to the arm with pin (A) and then pin (B 3. After confirming low oil temperature, remove the plug from the outlet and inlet port respectively. Take care that no dust, mud etc. adheres to the hose end portions. 4. If O-ring is damaged, replace it with a new one. 5. Connect the hose at the attachment side. When doing this, check the direction of flow of the oil and be careful not to make any mistake. 6.
Turn the rotor on the stop valve installed to the piping for the inlet port and outlet port on the side face of the arm to the FREE 7. position (F). 8. After installing the attachment, check the oil level in the hydraulic tank. PC400LC-7E0 5-15