Komatsu — SWING BRAKE CANCEL SWITCH

OPERATION EMERGENCY PUMP DRIVE SWITCH Remark This switch is installed to make it possible to carry out operation temporarily if any abnormality should occur in the pump control system. It is not intended for permanent use. Repair the cause of the abnormality immediately. If this switch is depressed and moved to the EMERGENCY position by mistake, thereby engaging the machine in the work, while the machine is in normal condition, a “E02” will be displayed. If “E02” is displayed during operation, check to be sure the switch is in the NORMAL position.

This switch (10) is used to make it possible to carry out operations temporarily if any abnormality should occur in the pump control system (when the display shows E02). When normal...................................................... Move switch down When abnormal....................................................... Move switch up If the display shows E02, move the switch up to make it possible to carry out work. SWING BRAKE CANCEL SWITCH Remark This switch is installed to make it possible to carry out operation temporarily if any abnormality should occur in the swing brake system. It is not intended for permanent use. Repair the cause of the abnormality immediately.

This switch (11) is used to make it possible to perform operations temporarily if any abnormality occurs in the swing brake system (when the display shows E03) When normal...................................................... Move switch down When abnormal....................................................... Move switch up If the display shows E03, move the switch up to make it possible to carry out work. When pushing this switch up to the FREE position, the swing lock monitor lamp begins to flash. 2-36 PC400LC-7E0