Kenworth — Kenworth T170 T270 T370 and Hybrid 2011 Body Builders Manual

Section 8 Electrical Note: All VCAN lines must conform to J1939-11 guidelines; this includes using a jacketed, shield- ed, twisted pair of wires. Keep the VCAN lines away from high current, rapidly switching loads and the wires connected to these devices. For more details about 1939-11 VCAN specifications please refer to SAE J1939-11. PTO Hybrid trucks have the option of two different PTO operation modes; they can be outfitted with either an Electronic PTO or a Mechanical PTO. ePTO EPTO uses the Hybrid Systems electric motor to turn the PTO gear in the transmission. A 3 way connector is provided on the Transmission Harness to interface with the PTO.

The connector provides the positive and negative signals to engage the PTO and an interlock to insure the PTO is engaged. The interlock circuit is a ground signal. This is typically done with a ball switch on the PTO. One side of the ball switch would be connected to ground and the other to Pin A. ePTO 3 way connector Pin A is for PTO interlock negative signal Pin B is for PTO solenoid Neg Pin C is for PTO solenoid Pos FIGURE 8-21. ePTO Harness Location mPTO MPTO operates like a normal PTO with the exception of the use of a PTO interlock circuit. The interlock circuit is a ground signal. This is typically done with a ball switch on the PTO.

One side of the ball switch would be connected to ground and the other to terminal P206 located LH side of the transmission on the hybrid transmission harness. 8-28 12/11