Section 8 Electrical Connecting the Liftgate Power Follow these instructions to connect the liftgate to the third battery. See Figure 8-26. 1. Install the third battery. 2. Positive battery jumper cable with ring terminal breakout wire, item 17 in Table 8-9, page 8-30, should be installed instead of item 2. 3. Install circuit breaker 4. Shorten the ring terminal breakout wire on positive battery jumper cable, item 17, to length as needed for rout- ing to the circuit breaker. Install ring terminal, item 18 as needed. Route the wire per routing requirements in Section 7. 5. Connect the ring terminal breakout wire to the circuit breaker.
The positive battery jumper cable with ring terminal breakout, item 17, and the ring terminal, item 18, are in Table 8-9, page 8-30. These are available form PACCAR Parts. The remainder of the wiring installation should be in accordance with the liftgate manufacturer’s installation instructions. Figure 8-26. Liftgate Circuit Breaker Inside Battery Box 8-32 12/11