Kenworth — Kenworth T170 T270 T370 and Hybrid 2011 Body Builders Manual

Section 4 Exhaust & Aftertreatment Measurement Reference Points For all relocation procedures, the measurement points will referenced in the guidelines are taken from the following spe- cific points: Supply Module: The supply module is commonly called a pump. The measurement point on the supply module is the top of the DEF fluid pressure line. See Figure 4-1. Figure 4-1: Measurement Location of DEF Supply Module (Pump) Dosing Module: The dosing module is commonly called an injector, this injector is located on the SCR mixing pipe which is between the DPF and SCR canister. The measurement point on the dosing module is the top of the DEF fluid pressure line. See Figure 4-2. Figure 4-2:

Measurement Location of DEF Dosing Module (Injector) The following relocation guidelines are dependant on exhaust configuration and DEF tank type and location. The Dosing Module should not need to be relocated. However if it is removed for any reason, it is critical that the module be reinstalled at the correct orientation. Figure 4-3 below illustrates the correct installation orientations. The angle refer- ences the vertical plane. 4-4 12/11