Komatsu — REPLACE AIR CLEANER ELEMENT

MAINTENANCE 5. Clean the interior of the air cleaner body, cover (3) and evacuator valve (6). The inner element must not be used again even after its cleaning. When replacing the outer element and seal (7) replace them at the same time. 6. Direct dry compressed air Max. 0.69 MPa 7 kgf/cm 2 (99.4 PSI) from the inside of the outer element along its folds. Then direct the compressed air from the outside along the folds, and again from the inside. A. Replace any outer element, which has been cleaned 6 times or used for one year. Replace the inner element at the same time. B.

Replace both inner and outer elements when the air cleaner clogging caution lamp lights up immediately after installing the cleaned outer element even though it has not been cleaned 6 times. 7. If small holes or thinner parts are found on the element when it is checked by shining a light through it after cleaning, replace the element. When cleaning the element, do not hit or beat it against anything. Do not use an element whose folds, gasket or seal are damaged. 8. Set the cleaned outer element in position, then secure cover (3) with mounting clips (2). REPLACE AIR CLEANER ELEMENT 1. Open the engine side cover on the right side of the machine. 2.

Remove three clips (2), then remove cover (3). 3-16 WA320PT-5L