MAINTENANCE FLUSHING THE COOLING SYSTEM Immediately after the engine is stopped, the engine coolant is hot and the pressure inside the radiator is high. Removing the cap and draining the water under this condition could cause burns. Allow the engine to cool down, then turn the cap slowly to release the pressure. Start the engine and flush the system. When standing up or leaving the operator's seat, set the safety lock lever to the LOCK position. For details of starting the engine. See CHECK BEFORE STARTING ENGINE, ADJUST (3-59) and STARTING ENGINE (3-72) in the OPERATION section of the Operation and Maintenance Manual. When the undercover is removed, there is danger of touching the fan.
Never go to the rear of the machine when the engine is running. To clean the inside of the cooling system, change the coolant and replace the corrosion resistor according to the table below. Stop the machine on level ground when cleaning or changing the coolant. Use a permanent type of antifreeze. If, for some reason, it is impossible to use permanent type antifreeze, use an antifreeze containing ethylene glycol. Super Coolant (AF- ACL) has an anti-corrosion effect as well as an antifreeze effect. The ratio of antifreeze to water depends on the ambient temperature, but to obtain the corrosion resistance effect, a minimum ratio of 30% by volume is necessary.
In areas where the water is hard, always add Komatsu genuine corrosion resistor agent KI. One packet of corrosion resistor agent contains 100g (0.22 lb). The standard density of the mixture should be 7g/liter (0.065 oz/US gal). When deciding the ratio of antifreeze to water, check the lowest temperature in the past, and decide from the mixing rate table given below. It is actually better to estimate a temperature about 10 0 C (50 0 F) lower when deciding the mixing rate.
Mixing Rate Of Water And Antifreeze Quantity Of Antifreeze To Be Added To The Water 3-18 WA320PT-5L Coolant Type Flushing System Corrosion Resistor (K1) Permanent type ant-freeze all season Every year (autumn) or every 200 hours whichever comes first Every 1000 hours and when cleaning the inside of the cooling system and when changing coolant Non-permanent type anti-freeze containing ethylene glycol (winter one season) Every 6 months (spring and autumn) Drain in spring and add anti-freeze in autumn Minimum ambient temperature ° C -4 -6 -9 -12 -16 -20 -26 -32 -36 ° F 25 21 15 10 3 -4 -15 -26 -33 Quantity of antifreeze Liter 1.4 2.1 2.8 3.5 4.2 4.9 5.6 6.3 7 US gal 0.37 0.55 0.74 0.92 1.11 1.29 1.48 1.66 1.85 Quantity of water Liter 12.6 11.9 11.2 10.5 9.8 9.1 8.4 7.7 7 US gal 3.33 3.15 2.96 2.78 2.59 2.41 2.22 2.04 1.85