MAINTENANCE Antifreeze is toxic. When removing the drain plug, be careful not to get water containing antifreeze on you. If it gets in your eyes, flush your eyes with large amount of fresh water and see a doctor at once. Use distilled water for the cooling water. Do not use river water, well water, contact your Komatsu Dealer. We recommend use of an antifreeze density gauge to control the mixing proportions. Prepare a container to catch drained coolant: Min. 20 liters (5.28 US gal) capacity. Prepare a water inlet hose. 1. Stop the engine. 2.
Check that the cooling water temperature has gone down enough to make it possible to touch the radiator cap surface by hand, then turn radiator cap (1) slowly until it contacts the stopper to release the pressure. 3. Following this, push radiator cap (1), turn it until it contacts the stopper, then remove it. 4. Set a container in position to catch drained antifreeze mixture, then open valve (2) under the radiator to drain cooling water. 5. After draining the water, close drain valve (2) and fill with distilled water. 6. When the radiator is full, start the engine, and run it at low idling.
Keep the engine running at low idling for 10 minutes until the water temperature reaches more than 90 0 C (194 0 F). 7. Stop the engine, open drain valves (2), drain the water, then tighten them again. 8. After draining the water, clean the cooling system with cleaning agent. For the cleaning method, see the instructions for the cleaning agent. 9. Decide the proportions of antifreeze and water according to the table for the mixing rate of water and antifreeze. 10. To remove the air in the cooling system, run the engine for 5 minutes at low idling, and for another 5 minutes at high adding. (When doing this, leave the radiator cap off.) 11.
After draining reserve tank (3), clean the inside of the reserve tank and refill the water between FULL and LOW level. 12. Stop the engine. About 3 minutes later, supply city water up to the water filler, then close radiator cap. WA320PT-5L 3-19