Komatsu — USING SWITCH TO CHANGE BETWEEN FORWARD AND REVERSE

3. Place the directional selector switch actuation switch (3) at the ON position (a). OPTIONAL ATTACHMENTS 4. Place the directional selector switch (2) at the F (forward) or R (reverse) position. When the directional selector switch actuation switch (3) is at the ON position, if the directional lever (1) is operated to FORWARD or REVERSE , the machine will travel in forward or reverse according to the operation of the directional lever, regardless of the position of the directional selector switch (2). Priority is given to the operation of the directional lever. When using directional selector switch (2) again, set directional lever (1) and directional selector switch (2) to the N position.

WA320PT-5L 5-11