DRESSTA TD20H98/1E — 5.10. ELECTRICAL SYSTEM

SECTION 5 MAINTENANCE Page 26 5.8. COOLING SYSTEM 2. Remove the radiator cap. Refer to ”RADIATOR CAP”. 3. Open the oil cooler drain valve located on the bottom of the oil cooler. 4. Open two crankcase drain valves, located at each side of the rear part of the crankcase. 5. Open radiator drain valve located on lower tank on R.H. side of the machine. Access to the valve is gained after removal of front bottom guard. 6. Allow the system to drain completely; do not let drain outlets plug up from foreign material. 7. Change coolant filter. Install a filter of greater capacity. (Procedure is shown in Engine Operation Manual). 5.8.8.2. Filling the Drained System 1.

Close the oil cooler drain valve, radiator drain valve and two crankcase drain valves. 2. Fill the cooling system slowly. This allows more air to escape and the system to be filled to maximum capacity. The percentage of antifreeze to add for freeze protection can be determined from the antifreeze and coolant chart. Refer to „ANTIFREEZE”. 3. Start engine and run until normal operating temperature is reached; adding coolant when needed to keep proper level of 25 mm above the baffle. 4. After all air is removed and level remains fixed, install the radiator cap. 5.9. FAN AND FAN HUB Fig. 5.10. Fan WARNING! Keep clear of fan and fan belts when engine is running.

Rotating fan and belt contact can cause injury. 1. Check the condition of fan blades (cracks, damaged, rivets, loosen mounting bolts) and bearing of idler pulley. 2. Reversible fan blades (if equipped) should be after every 250 hours reversed to prevent excessive contamination in engine and cooler compartment. After reversing the blades adjust them in required position. 5.10. ELECTRICAL SYSTEM Precautions WARNING! BEFORE WORKING ON THE ENGINE OR ELECTRICAL SYSTEM, turn off the electrical system master switch and remove the key. All terminals must be clean and fastened securely. Replace frayed, cracked, and poorly insulated wiring. TD-20H DRESSTA