SECTION 5 MAINTENANCE Page 18 5.6. AIR CLEANING SYSTEM Installation (Fig. 5.2.) 1. Install new safety element (7) into the body (8) and secure with nut (6). 2. Install a new primary filter element (5) onto safety element (7) and secure it with wing nut (4). 3. Install cover (2) and secure it with nut making sure cover is not cocked. 5.6.4. AIR INTAKE SYSTEM 5.6.4.1. Precleaner Fig. 5.3. Precleaner Assembly 1. Precleaner Filter 2. Air Cleaner 3. Air Intake Tube Clamps The dome of the precleaner hood serves as a rain shield and the screen prevents chaff and course dirt from getting into the air cleaner. Keep this screen clean from all chaff, oil or dust.
Clogged holes in the screen will reduce the power of the engine by restricting the flow of air. Loosen the clamp screw on the precleaner hood. Twist and pull upward to remove the cap. Use compressed air to clean the screen. If compressed air is not available, wash in clean hot water or water containing a small amount of nonsudsing detergent. IMPORTANT: Never wash precleaner installed on the machine as water may penetrate to the engine. 5.6.4.2. Checking air intake system for leaks Air intake system leakproof tests must be performed after each Disassembly of intake system or if necessary (leaks or loosens clamps). 1. Remove cover from the air cleaner body. 2. Remove primary element. 3.
Mask the entire perforated metal outside diameter of safety element (smaller) with the duct tape and reinstall. Sealing must be airtight. Connect regulated compressed air supply to one of existing connecting ports on air intake manifold. Connect pressure gauge to other connecting port on intake manifold or to warning light switch. TD-20H DRESSTA