screw it off yet. Table of Illustration 4 3 5.2.2 Hydraulic system 2 1 Illustration Maintenance work: Changing the hydraulic oil and the oil filter 50 operating hours after t he initial operation and subsequently, at intervals of 500 operating hours 4 3 2 1 NOTE! i Prior to carrying out any maintenance work at the hydraulic system, be sure to consult the Table of lubricants for information on the specifications of the required hydraulic oils. Slightly loosen the oil filter cartridge (3) by means of a tension band or a similar tool, but do not screw it off yet. i NOTE!
In order to prevent the contents of the suction pipe from leaking, stop loosening the filter cartridge as soon as a suction sound is audible. The air intake causes the oil in the suction pipe to flow back into the tank. • As soon as the suction sound stops, unscrew the oil filter cartridge and dispose of it in an eco-friendly way. EU waste disposal key: 150299 (EU). • Use clean oil to lubricate the sealing of the filter head (4). • Lubricate the new oil filter cartridge (3) with clean hydraulic oil. • Attach the new oil filter cartridge and screw it on by hand. i NOTE! Do not use a tension band to screw on the filter cartridge! Checking the hydraulic oil level:
• Screw off the oil filler neck with the oil dipstick ( 1) and check the oil level. • If necessary, add hydraulic oil. • Clean the ventilation head (2). • In case you need to add hydraulic oil, refer to the Table of lubricants for the required oil specifications. Maintenance work 5 - 15 Issue: 02-10