Komatsu — EVERY 250 HOURS SERVICE

. MAINTENANCE SERVICE PROCEDURE CHECK BATTERY ELECTROLYTE LEVEL Perform this check before operating the machine. WARNING the UPPER LEVEL line. If the NOTICE When adding distilled water in cold weather, add it before starting operations in the morning to prevent the electrolyte from freezing. 3. If the electrolyte level is below the midway point between the UPPER LEVEL (U.L.) and LOWER LEVEL (L.L.) lines, remove cap (1) and add distilled water to the U.L. line. 4. If distilled water has been added to any cell of cap (1), add distilled water also to the other cells. 5. Clean the vents of the battery caps, then close the caps securely.

Keep the top of the battery clean and wipe it with a wet cloth. to the UPPER 4 - 42 EVERY 250 HOURS SERVICE Maintenance for every 50 and 100 hours service should be carried out at the same t Do not use the battery i f the battery electrolyte level is below the LOWER LEVEL line. This w i nside of the battery an d reduce the service life of the battery. In addition, it may cause an e The battery generates f lammable gas and there is danger of explosion, do not bring fire or s Battery electrolyte is da ngerous. If it gets in your eyes or on your skin, wash it off with a lar doctor.

When adding distilled water to the battery, do not allow the battery electrolyte to go abov electrolyte level is too h igh, it may leak and cause damage to the paint surface or corrode o Inspect the battery elec trolyte level at least once a month and follow the basic safety WHEN CHECKING ELECTROLYTE LEVEL FROM SIDE OF BATTERY If it is possible to check the electrolyte level from the side of the battery, check as fo 1. Open the cover of the battery box. There are two battery boxes: One on each side at the rear of the machine. 2.

Use a wet cloth to clean the area around the electrolyte level lines and check that the electrolyte level is between the UPPER LEVEL (U.L.) and LOWER LEVEL (L.L.) lines. If the battery is wiped with a dry cloth, static electricity may cause a fire or explosion. . Open the cover of t There are two batte REMARK If distilled water is adde d to above the UPPER LEVEL (U.L.) line, use a syringe to l If d LEVEL (U.L.) line. Neu tralize the removed fluid with baking soda (sodium bicarbon large amount of water o r consult your Komatsu distributor or battery maker.