REFERENCE ONLY .l~ ~ l8 ,~; .....::!! u w 0 . :'i on - z ~, =? IX) m ~ " 3: a: 140497 PN=50 Sll.0MLM.C -19-09AUG94 ~ IT:: ~, Sll.0MLM.AP -19-22FEB93 Lubrication and Maintenance/100 Hour A-Release Bearing Grease Fitting B-Fittings for Side-Loaded Drive C-Fittings for In-Line Drive D-Lever Shaft Fittings IMPORTANT: Lubricate release bearing fitting (A) daily or at 10 hour intervals for continuous operation. (See Prestarting Checks Section.) Lubricate shaft fittings (0) at 600 Hours or 1-Year intervals. (See LUBRICATE PTa CLUTCH SHAFT BEARINGS in 600 Hour/1-Year Service Section.) Read and follow the instructions which are packaged with it.
The extinguisher should be inspected at least every 100 hours of engine operation or once a month. Once extinguisher is operated, no matter how long, it must be recharged. Keep record of inspections on the tag which comes with the extinguisher instruction booklet 42 Apply one or two shots of John Deere Multipurpose Lubricant or its equivalent at clutch drive shaft bearing fittings (8 'or C). DO NOT over-lubricate to avoid getting oil on clutch facings. A fire extinguisher (A) is available from your authorized servicing dealer or engine distributor_ LUBRICATE PTO CLUTCH SHAFT BEARINGS SERVICING FIRE EXTINGUISHER