hitachi — Transmission Learning

OPERATIONAL PERFORMANCE TEST / Adjustment Error Display When calibration fails, the error is displayed on the monitor. The error consists of two types; when start of calibration fails, when calibration is aborted during calibration. Error display when start of calibration fails If the error display as figure 1 is displayed before starting calibration, calibration cannot be continued. After the trouble correspoding to error No. is solved, start calibration again. Figure 1 Error Display T4GB-04-06-009 Figure 2 Error No. *1: Error No. and T/M temperature at this time (figure 2) are displayed alternately. *2: Error No. and engine speed at this time (figure 3) are displayed alternately. NOTE:

If error No. 2, 3 or 4 is displayed, set the switch and lever corresponding to this error to the correct position so that SR is displayed on the monitor. If error No. 6 is displayed, wait until transmission oil temperature reaches specification so that SR is displayed on the monitor. When SR is displayed, push the calibration start switch again and start calibration. T4GB-04-06-010 Figure 3 T4GB-04-06-011 T4-6-3 Error No. Error 2 The forward/reverse lever is not in “N”. 3 The parking brake is not in “ON”. 4 The machine is driving. 5 T/M temperature is lower than specification. *1 6 T/M temperature is higher than specification. *1 7 Engine speed is lower than specification.

*2 8 Engine speed is higher than specification. *2 3 T/M Temperature T4G Engine Speed T4G