hitachi — Transmission Learning

OPERATIONAL PERFORMANCE TEST / Adjustment Learning 1. Install the calibration switch to the connector (6-pole, gray) in relay box in 10 seconds after turning the key switch OFF (the battery relay is tuned OFF). At this time, return the calibration start switch to neutral. IMPORTANT: If the battery relay is not turned OFF, calibration cannot be performed. It takes 10 seconds to turn the battery relay OFF after turning the key switch OFF. 2. Start the service mode in monitor. Start the engine. Set engine speed at idling speed. (Refer to T5-1-6.) 3. Select the transmission oil temperature on the monitor. (Refer to T5-1-7.) IMPORTANT:

Do not operate each switch and lever until calibration finishes. 4. When transmission oil temperature reaches 75 ° C (167 ° F), push T/M in the calibration start switch. The start of learning display as illustrated in the right is selected on the monitor. 5. When learning finishes, the end of learning display as illusrated in the right is selected on the monitor. Return the calibration start switch to neutral. 6. Remove the calibration switch from the connector and stop the engine. T4GB-04-06-003 Start of Learning Oil temperature when starting learning The speed stage during learning is displayed on the monitor. 11 to 13: First Gear, 21 to23: Second Gear, 31 to 33: Third Gear, 41 to 43:

Fourth Gear, F1 to F3: Forward, A1 to A3: Reverse End of Learning T4GB-04-06-004 T4GB-04-06-006 T4-6-2 Calibration Switch C S Lift Arm T/M C S alibration Start witch e n g