TROUBLESHOOTING/ Troubleshooting A Fault Code Remark 100-4 100-3 105-3 105-4 Operating Rank A: Digging and travel are operable. (A few performance decreases may occur.) B: Machine can travel on flat and downward slope. C: The engine can stop / start. D: The engine cannot stop / start. IMPORTANT: When fault code 723-2 (abnormal crank speed sensor) is displayed and the engine does not start, the cam angle sensor is faulty although fault codes 636-2 (abnormal cam angle sensor) and 636-7 (phase mismatch of cam angle sensor) are not displayed.
T5-5-27 Trouble Influence to Engine Performance (Presumption) Operating Rank (Current State) A B C D Abnormal Engine Oil Pressure Sensor (Abnormal High Voltage) No output power change ○ Abnormal Engine Oil Pressure Sensor (Abnormal Low Voltage) ○ Abnormal Boost Temperature Sensor (Abnormal High Voltage) ○ Abnormal Boost Temperature Sensor (Abnormal Low Voltage) ○