hitachi — ECM Fault Code List

TROUBLESHOOTING/ Troubleshooting A Operating Rank A: Digging and travel are operable. (A few performance decreases may occur.) B: Machine can travel on flat and downward slope. C: The engine can stop / start. D: The engine cannot stop / start. T5-5-40 Fault Code Trouble Influence to Engine Performance (Presumption) Operating Rank (Current) Remark A B C D 10005-1 Abnormal Charge Circuit (Bank 1) Output power decrease: 60% (Three cylinders drive.) ○ ○ 10006-1 Abnormal Charge Circuit (Bank 2) ○ ○ 10008-2 Abnormal A/D Converter Output power decrease: 50% ○ 10007-2 Abnormal CPU Output power decrease: 50% ○ The engine cannot start. ○ 1077-2 Abnormal IC for CPU watching Output power decrease:

50% ○ 628-2 Abnormal ROM The engine stops. ○ 10013-2 Abnormal EEPROM No output power decrease ○ 1079-2 Abnormal 5 V Power Source 1 Voltage Idle speed operation ○ 1080-2 Abnormal 5 V Power Source 2 Voltage No output power decrease ○ 10009-2 Abnormal 5 V Power Source 3 Voltage No output power change ○ 10010-2 Abnormal 5 V Power Source 4 Voltage No output power decrease ○ 10011-2 Abnormal 5 V Power Source 5 Voltage Output power decrease: 50% ○ ○ 10003-2 Abnormal Injection Nozzle Common 1 Drive System Output power decrease: 60% (Three cylinders drive.) ○ ○ 10004-2 Abnormal Injection Nozzle Common 2 Drive System ○ ○