TROUBLESHOOTING / Troubleshooting A MC FAULT CODE 11413 valve · Between terminal #A5 of connector MC-A in MC and terminal #2 of connector in pump torque control solenoid valve Connector (Harness end of connector viewed from the open end side) MC Connector MC-A #A5 T183-05-04-008 #A31 Pump Torque Control Solenoid Valve T5-5-82 Fault Code Trouble Cause Influenced Control 11413-2 Abnormal Feedback of Pump Torque Control Solenoid Valve The feedback current to MC becomes the uncertain value. • Pump Standard Torque Control 11413-3 Abnormal Feedback High Current of Pump Torque Control Solenoid Valve The feedback current to MC is beyond the upper limit.
• Pump Standard Torque Control 11413-4 Abnormal Feedback Low Current of Pump Torque Control Solenoid Valve While the command from MC is output, the feedback current to MC is 56 mA or less. • Pump Standard Torque Control Switch connectors of NO Faulty pump torque pump torque control control solenoid valve. solenoid valve and normal YES solenoid valve. Retry. Faulty MC. Check if fault code disappears. YES Check for continuity in harness between MC and pump torque control solenoid valve. · Between terminal #A31 of connector MC-A in MC and terminal #1 of Open circuit in harness. connector in pump torque control solenoid NO NO Faulty pump torque control solenoid valve. Open circuit in harness.
NO 1 2