TROUBLESHOOTING / Troubleshooting A PROPORTIONAL SOLENOID VALVE FAILURE MC FAULT CODE 11412 drive fan flow rate control solenoid valve · Between terminal #A29 of connector MC-A in MC and terminal #2 of connector in hydraulic drive fan flow rate control solenoid valve Connector (Harness end of connector viewed from the open end side) MC Connector MC-A #A32 #A29 T183-05-04-008 Hydraulic Drive Fan Flow Rate Control Solenoid Valve Connector T5-5-81 Fault Code Trouble Cause Influenced Control 11412-2 Abnormal Feedback of Hydraulic Drive Fan Flow Rate Control Solenoid Valve The feedback current to MC becomes the uncertain value.
Hydraulic Drive Fan Cooling Control 11412-3 Abnormal Feedback High Current of Hydraulic Drive Fan Flow Rate Control Solenoid Valve The feedback current to MC is beyond the upper limit. Hydraulic Drive Fan Cooling Control 11412-4 Abnormal Feedback Low Current of Hydraulic Drive Fan Flow Rate Control Solenoid Valve While the command from MC is output, the feedback current to MC is 56 mA or less. Hydraulic Drive Fan Cooling Control Switch connectors of Faulty hydraulic drive fan hydraulic drive fan flow NO flow rate control solenoid rate control solenoid valve. valve and normal YES solenoid valve. Retry. Faulty MC. Check if fault code disappears.
YES Check for continuity in harness between MC and hydraulic drive fan flow rate control solenoid valve. · Between terminal #A32 of connector MC-A in MC and terminal #1 of Open circuit in harness. connector in hydraulic NO Open circuit in harness. NO 1 2