TROUBLESHOOTING / Troubleshooting A Connector (Harness end of connector viewed from the open end side) MC Connector MC-A #A10 #A9 #A6 #A3 #A11 #A15 #A16 #A17 #A19 #A20 #A22 T183-05-04-008 #A30 Proportional Solenoid Valve Connector List of connection relationship between each proportional solenoid valve connector terminal and connector MC-A terminal T5-5-85 NO Faulty proportional Switch proportional solenoid valve. solenoid valve with YES normal one and retry. Check if fault code disappears. Faulty MC. YES Check for continuity in harness between MC and proportional solenoid valve. · Refer to tabel below. Open circuit in harness. NO NO Faulty proportional solenoid valve.
Open circuit in harness. NO 1 2 First Gear Proportional Solenoid Valve Connector Second Gear Proportional Solenoid Valve Connector Third Gear Proportional Solenoid Valve Connector Fourth Gear Proportional Solenoid Valve Connector Forward Proportional Solenoid Valve Connector Reverse Proportional Solenoid Valve Connector #1 #2 #1 #2 #1 #2 #1 #2 #1 #2 #1 #2 Connector MC-A #A10 #A6 #A22 #A16 #A20 #A3 #A11 #A17 #A30 #A19 #A9 #A15