hitachi — CAN Harness Check(MC Fault Codes 11910, 11920)

TROUBLESHOOTING / Troubleshooting A CAN HARNESS CHECK MC FAULT CODES 11910, 11920 • Check the wiring connections first. YES Shorted circuit in CAN harness between ground circuit and CAN circuit. Disconnect all connectors of MC, ICF, ECM and monitor unit. Check for continuity between ground circuit (MC, ICF, ECM, monitor unit) and CAN circuit. YES To A · Key switch: OFF · Refer to “Continuity Check in CAN Harness” on T5-5-59. Retry by using Dr. ZX. Check if fault code 11004-2 is displayed. · Key switch: OFF · Refer to “Discontinuity Check between CAN Circuit and Ground Circuit” on T5-5-61 to 65. · Key switch:

OFF · Refer to “Discontinuity Check between CAN Circuit and Power Circuit” on T5-5-66 to 69. NO Open circuit in CAN harness between MC and ECM. NO Normal. YES Shorted circuit in CAN harness between power circuit and CAN circuit. YES Shorted circuit in CAN harness between key signal circuit and CAN circuit. A and CAN circuit. YES Shorted circuit in CAN harness. · Key switch: OFF · Refer to “Discontinuity Check between CAN Circuit and Key Signal Circuit” on T5-5-70 to 72. YES To B · Key switch: OFF · Refer to “Discontinuity Check in CAN Harness” on T5-5-73. Disconnect connector in MC. Connect connector of harness end.

Check if resistance between terminals #18 and #37 of connector in ECM is within 120 ± 10 Ω . To C NO · Key switch: OFF · Key switch: OFF T5-5-92 Check for continuity between power circuit MC, ICF, NO ECM, monitor unit and CAN circuit. Check for continuity in CAN harness between YES MC and ECM. Check for continuity between key signal circuit in MC, ICF, NO E Check for continuity between High side NO and Low side in CAN harness. Connect all connectors except connector MC-C in MC. Check if resistance between terminals #C4 NO and #C15 of harness end of connector MC-C is within 60±10 Ω.