TROUBLESHOOTING / Troubleshooting A CAN HARNESS CHECK FAULT CODE 11914 Check the wiring connections first. Disconnect all connectors of MC, ICF, ECM and monitor unit. Check for continuity between ground circuit MC, ICF, ECM, monitor unit and CAN circuit. YES Open circuit in CAN harness between ground circuit and CAN circuit. YES · Key switch: OFF · Refer to “Discontinuity Check between CAN Circuit and Power Circuit” on T5-5-66 to 69. To A · Key switch: OFF · Refer to “Discontinuity Check between CAN Circuit and Ground Circuit” on T5-5-61 to 65. · Key switch: OFF · Refer to “Continuity Check in CAN Harness” on T5-5-60. Retry by using Dr. ZX. Check if fault code 11004-2 is displayed.
Open circuit in CAN harness between MC and monitor unit. NO Normal. NO YES Shorted circuit in CAN harness between power circuit and CAN circuit. YES Shorted circuit in CAN harness between key signal circuit and CAN circuit. A YES Shorted circuit in CAN harness. · Key switch: OFF · Refer to “Discontinuity Check between CAN Circuit and Key Signal Circuit” on T5-5-70 to 72. YES · Key switch: OFF · Refer to “Discontinuity Check in CAN Harness” on T5-5-73. Connect connector in MC. Disconnect connector monitor-2B in monitor unit. Check if resistance between terminals #B33 and #B34 of harness end of connector is within 120 ± 10 Ω . To B NO To C · Key switch: OFF · Key switch:
OFF T5-5-96 Check for continuity between power circuit MC, ICF, NO ECM, monitor unit and CAN circuit. Check for continuity in CAN harness between YES MC and monitor unit. Check for continuity between key signal circuit in MC, ICF, NO ECM, monitor unit and CAN circuit. Check for continuity between High side and Low side in CAN NO harness. Connect all connectors except connector MC-C in MC. Check if resistance NO between terminals #C4 and #C15 of harness end of connector MC-C is within 60±10 Ω.