hitachi — CAN Harness Check(MC Fault Code 11914)

TROUBLESHOOTING / Troubleshooting A NO Check the connections of monitor unit and connector. · Key witch: ON YES Faulty monitor unit. C NO Check the connections of ICF and connector. YES Faulty ICF. · Key witch: ON Connect connector in ECM. Disconnect connector ICF-C in ICF. Check if resistance between terminals Check the connections of ICF and connector. · Key witch: OFF · Key witch: ON NO Faulty In any controller in MC, ICF, ECM or monitor unit. · Key witch:

OFF Connector MC Connector MC-C (Harness end) ECM Connector (Harness end) #18 #37 #C15 #C4 C23 C31 T1GR-05-04-002 Monitor Unit Connector Monitor-2B (Harness end) ICF Connector ICF-C (Harness end) #C5 #C11 T1V1-05-04-002 T4GB-05-05-002 T5-5-97 Connect connector in MC. Check if fault B code 11004-2 is displayed. · Key witch: ON NO Check the connections of MC and connector. Faulty MC. YES Connect connector in monitor unit. Check if fault code YES 11004-2 is displayed. Connect connector in ECM. Check if fault code YES 11004-2 is displayed. Connect connector in monitor unit. Disconnect connector ECM.

Check if resistance between terminals #18 and #37 of NO harness end of connector is within 120±10 Ω. Connect connector in ICF. YES Check if fault code 11004-2 is displayed. NO Faulty ICF. ES NO #C5 and #C11 of harness end of connector is within 60±10 Ω. C1 C10 # #C #B34 #B33