hitachi — Proportional Solenoid Valve TrubleCheck

TROUBLESHOOTING / Troubleshooting A PROPORTIONAL SOLENOID VALVE TROUBLE CHECK When the harness in proportional solenoid valve is faulty, the fault code may be not detected. If the trouble is related to the proportional solenoid valve, disconnect the connectors in MC and proportional solenoid valve. Then check for continuity. MC Proportional Solenoid Valve A B D C T1V1-05-06-008 : Fault code can be detected. : Fault code can be detected according to trouble. Ч : Fault code cannot be detected.

T5-5-100 Circuit Condition in Trouble Trouble Fault Code Damaged Parts in MC A B D C T1V1-05-06-006 Open circuit in A-B △ None A B D C T1V1-05-06-007 • Open circuit in A-B • Harness in side B is shorted to the ground. ○ None A B D C T1V1-05-06-009 • Open circuit in A-B • Harness in side A is shorted to the ground. △ FET A B D C T1V1-05-06-010 Shorted circuit in A-B ○ FET A B D C T1V1-05-06-011 Open circuit in C-D △ None A B D C T1V1-05-06-012 • Open circuit in C-D • Harness in side C is shorted to the ground. △ None A B D C T1V1-05-06-013 • Open circuit in C-D • Harness in side D is shorted to the ground. ○ None A B D C T1V1-05-06-014 Shorted circuit in C-D △ None