hitachi — Front Attachment SystemTroubleshooting

TROUBLESHOOTING / Troubleshooting B F-3 Certain front attachment is slow / weak. If the lift arm or the bucket is normal, the pilot pump (primary pilot pressure) should be normal. If there is malfunction in the pilot poppet valve in main relief valve, operating speed with light load may be normal. Clogged or stuck bucket flow rate con- trol valve (check, ori- fice, spool). YES Check if bucket op- eration is worse only during combined operation of lift arm raise and bucket. YES Stuck spool in control valve or faulty cylinder (faulty seal kit). NO YES Check if overload relief valve pressure is normal. · In case of lift arm, load check valve may be stuck.

· Refer to Operational Performance Test section. Check if secondary pilot pressure in pilot circuit which trouble occurs is normal. Faulty overload relief valve or make-up valve. NO · Engine: Running · Secondary pilot pres- sure: Refer to opera- tional Performance Test section. Faulty pilot valve. NO · In case of lift arm, re- striction valve may be stuck. T5-6-44