TROUBLESHOOTING / Troubleshooting B TRAVEL SYSTEM TROUBLESHOOTING T-1 Machine does not travel forward/ re- verse. Machine can travel only when the following con- ditions are present. Forward/Reverse Lever: F or R Parking Brake Switch: OFF If the front attachment operation is normal, the engine system and the pilot oil supply system may be normal. Check the wiring connections first. If the followings are normal, the transmission and axles (front, rear) may be faulty. Check for ab- normal sound at each part. To A T5-6-60 NO Check if front speed is within specification. · Engine: Running Operate brake pedal.
· Refer to the Opera- NO Check if brake pedal is tional Performance operated heavily with Test section. work brake applied. · Engine: Running Check if trouble occurs; Faulty service brake. although machine YES cannot travel by using YES forward/reverse switch, machine can travel by using forward/reverse lever. Faulty forward/reverse switch or forward/reverse YES Monitor pedal brake lever, or faulty harness. pressure of MC monitor item on Dr. ZX. Check if pressure is 0 MPa. Engine: Running YES Faulty brake valve. Check if port pressure at brake pedal outlet or NO brake pressure inlet in axle exists.
· Engine; Running Faulty service brake · Tow the machine to level pressure sensor or ground and execute this shorted circuit in harness NO item. (Refer to the opera- between MC and brake tional manual.) pressure sensor. Check if front speed is within specification. Faulty service brake pressure sensor or shorted circuit in harness between MC and brake pressure sensor.