TROUBLESHOOTING / Troubleshooting B YES Faulty TCU. Monitor transmis- sion output speed of TCU monitor item on Dr. ZX. Check if speed be- low is displayed on of Dr. ZX screen when traveling at 10 km/h. A YES Faulty travel speed sensor. If travel speed in- creases or decreases at former section, dis- play on Dr. ZX is shifted. · ZX220: 880 min -1 ZX250: 910 min -1 NO Faulty travel speed sensor, or faulty harness between travel speed sensor and MC. NO YES Faulty ride control valve. Check for continuity in harness between MC and ride control pro- portional solenoid valve. NO Replace ride control proportional solenoid valve with normal one. Check if ride control is operated properly.
Faulty harness be- tween MC and ride control proportional solenoid valve. YES · Between terminals #A23 (#A7) of connec- tor MC-A in MC and #1 (#2) in ride control proportional solenoid valve NO Check if ride control accumulator gas pressure is 3 MPa (31 kgf/cm 2 ). B Faulty ride control proportional solenoid valve. YES Replace ride control accumulator. NO Proportional Solenoid Valve Connector #2 #1 T5-6-59 2 1