TROUBLESHOOTING / Troubleshooting B T-3 Machine moves with lever in neutral. YES Faulty forward/reverse lever. Monitor selected travel speed gear of MC monitor item on Dr. ZX. Check if item except N is displayed. YES Monitor actual travel speed gear of MC monitor item on Dr. ZX. Check if item except N is displayed. · Travel: Forward NO Faulty MC. NO YES Faulty transmission con- trol valve. · Travel: Forward · Forward/reverse lever: Neutral Replace transmission control valve with nor- mal one. Check if ma- chine operation be- comes normal. Turn forward/reverse switch ON. Check if machine moves. NO NO Faulty transmission. Faulty MC. YES T5-6-63