TROUBLESHOOTING / Troubleshooting B Alarm Data As for inspection method of the CAN line, refer to Troubleshooting A group in TROUBLESHOOTING section.
T5-6-126 Data Input Signal 1 Overheat alarm Check terminals #C5, #C11 of connector ICF-C in ICF, terminals #33, #34 of connector monitor-2 in monitor unit 2 Engine warning alarm Check terminals #C5, #C11 of connector ICF-C in ICF, terminals #33, #34 of connector monitor-2 in monitor unit 3 Engine oil pressure alarm Check terminals #C5, #C11 of connector ICF-C in ICF, terminals #33, #34 of connector monitor-2 in monitor unit 4 Alternator indicator alarm Check terminals #C5, #C11 of connector ICF-C in ICF, terminals #33, #34 of connector monitor-2 in monitor unit 5 Air cleaner restriction alarm Check terminals #C5, #C11 of connector ICF-C in ICF, terminals #33, #34 of connector monitor-2 in monitor unit 6 Water separator alarm Check terminals #C5, #C11 of connector ICF-C in ICF, terminals #33, #34 of connector monitor-2 in monitor unit 7 Service brake oil level alarm Check terminals #C5, #C11 of connector ICF-C in ICF, terminals #33, #34 of connector monitor-2 in monitor unit 8 Service brake oil pressure alarm Check terminals #C5, #C11 of connector ICF-C in ICF, terminals #33, #34 of connector monitor-2 in monitor unit 9 Emergency steering operation alarm Check terminals #C5, #C11 of connector ICF-C in ICF, terminals #33, #34 of connector monitor-2 in monitor unit 10 Steering oil pressure alarm Check terminals #C5, #C11 of connector ICF-C in ICF, terminals #33, #34 of connector monitor-2 in monitor unit 11 Transmission oil temperature alarm Check terminals #C5, #C11 of connector ICF-C in ICF, terminals #33, #34 of connector monitor-2 in monitor unit 12 Hydraulic oil temperature alarm Check terminals #C5, #C11 of connector ICF-C in ICF, terminals #33, #34 of connector monitor-2 in monitor unit 13 Transmission filter restriction alarm Check terminals #C5, #C11 of connector ICF-C in ICF, terminals #33, #34 of connector monitor-2 in monitor unit 14 Transmission malfunction alarm Check terminals #C5, #C11 of connector ICF-C in ICF, terminals #33, #34 of connector monitor-2 in monitor unit