TROUBLESHOOTING / Electrical System Inspection CHECK BY FALSE SIGNAL Turn the key switch OFF and disconnect the sensor connector. Turn the key switch ON. Connect terminal of power source and signal terminal on machine har- ness end connector. (Power voltage is used as a false signal.) Check this state by using the monitor function of Dr. ZX. If the displayed value is the maximum value, the circuits up to MC and machine harness end connector are normal. If “ON” is displayed, the pressure switch circuits are normal. IMPORTANT:
Altough terminal #1 is the teminal of power source, terminal #2 is the signal and #3 is the ground terminal respectively on the illustlation, all the connectors are not arranged similarly. Before measurement, check the electrical circuit diagram for the connector to be measured. IMPORTANT: Do not connect terminal of power source and signal terminal to ground terminal or to the vehicle frame (ground) when checking a three-polarity connector. Two Polarities 2 1 Connect T107-07-05-011 NOTE: Some kinds of sensors can be monitored by using the service mode of monitor.
(Refer to the TROUBLESHOOTING / Di- agnosing Procedure group.) T5-8-17 Power Source Three Polarities T107-07-05- Power Source Signal Ground 1 2 3 Connect Source S ignal Ground