hitachi — Main Relief Valve Set Pressure

OPERATIONAL PERFORMANCE TEST / Component Test MAIN RELIEF PRESSURE The main relief pressure can also be measured by using Dr. ZX. Summary: Measure the main relief valve set pressure at the main pump delivery port in order to check perform- ance of the main relief valve. Preparation: 1. Stop the engine. 2. Push the air bleed valve on top of the hydraulic oil tank and release any remaining pressure. 3. Remove the plug from the main pump delivery port. Install an adapter, a hose and a pressure gauge. Pressure Gauge : 6 mm (If Dr. ZX is used, install Dr. ZX and select the controller function diagnosing.) 4. Start the engine. Check for any oil leaks at the pressure gauge connection. 5.

Maintain the hydraulic oil temperature at 50 ± 5 ° C (122 ± 41 ° F). Measurement: 1. Set engine speed at fast idle. Depress the accel- erator pedal fully. 2. Slowly operate the lift arm or bucket control lev- ers to the stroke end (extend or retract) and re- lieve each function. 3. Repeat the measurement three times and calcu- late the average values. Evaluation: Refer to the Performance Standard Table in Group T4-2. Pressure Check Port T4GB-04-05-008 Adapter T4-5-8