hitachi — Main Relief Valve Set Pressure

OPERATIONAL PERFORMANCE TEST / Component Test Main Relief Valve Pressure Adjustment Proce- dure ZW220 1. Secure lock nut (1). Remove nut (3). : 17 mm 2. Secure adjusting screw (2). Loosen lock nut (1). : 17 mm 3. Turn adjusting screw (2) and adjust the relief pressure to the specification. 4. Secure adjusting screw (2). Tighten lock nut (1). : 19.5 N m (2 kgf m, 14 lbf ft) 5. Secure lock nut (1). Tighten nut (3). 6. Check the relief set pressure. T4GB-04-05-009 NOTE: