OPERATIONAL PERFORMANCE TEST / Component Test ZW250 1. Loosen lock nut (1). : 17 mm 2. Turn adjusting screw (2) and adjust the relief pressure to the specification. 1 : 6 mm 3. Tighten lock nut (1). : 29.4 N m (3 kgf m, 22 lbf ft) 4. Check the relief set pressure. 2 T4GB-04-05-011 NOTE: Standard Change in Pressure (Reference) Turns 1 Change in Pressure (2588) 17.8 (182) 2 Pressure Increase Pressure Decrease W107-02-05-129 T4-5-10 1/4 1/2 3/4 MPa (kgf/cm2) (psi) 4.5 (46) (654) 8.9 (91) (1294) 13.4 (137) (1948)