OPERATIONAL PERFORMANCE TEST / Component Test OVERLOAD RELIEF VALVE SET PRESSURE Summary: 1. The circuit pressure must be increased by applying an external force while blocking the return circuit from the control valve. This measuring method is hazardous and the results obtained with this method are unreliable. 2. The oil flow rate used to set the overload relief pressure is far less than that used to set the main relief pressure. Therefore, measuring the overload pressure in the main circuit by increasing the main relief set-pressure more than the overload valve set-pressure is not a proper method.
In addition, in case a main relief valve designed to leak a small quantity of oil before reliving is used, its pre-leaking start pressure must be increased more than the overload relief valve set-pressure. However, the pre-leaking start pressure is not always increased more than the overload relief valve set-pressure as the adjustable upper limit of the main relief valve set-pressure is provided. Accordingly, the overload relief valve assembly should be removed from the machine and checked on a specified test stand at a correct oil flow rate. Some overload relief valves come in contact with the control valve body to block the oil passage.
When this type of overload relief valve is checked, the control valve body must be precisely finished as the test unit. Provide one control valve other than that on the machine as a test kit. 3. If the overload relief valve performance must be checked on the machine, however, measure the main relief pressure while releasing each front function respective to the measuring overload relief valve. And, assume that the overload relief valve is functioning correctly if the obtained main relief pressure is within the specified value range. Measure the main pressure of the front functions by using Dr. ZX. Preparation: 1. Stop the engine. 2.
Push the air bleed valve on top of the hydraulic oil tank and release any remaining pressure. 3. Remove the plug from the main pump delivery port. Install an adapter, a hose and a pressure gauge. 4. Install Dr. ZX and select the monitoring function. Start the engine. Check for any oil leaks at the pressure gauge connection. 5. Maintain the hydraulic oil temperature at 50 ± 5 ° C (122 ± 41 ° F). Measurement: 1. Set engine speed at fast idle. Depress the accelerator pedal fully. 2. Slowly operate the control levers (lift arm or bucket) corresponding to the overload relief valve to be measured to the stroke ends (extend and retract) and relieve each function. 3.
Read the pressures on the pressure gauge at this time. 4. Repeat the measurement three times and calculate the average values. Evaluation: Performance of the overload relief valves are normal if the measured main relief pressures are within the specified value range. Refer to the Performance Standard Table in Group T4-2. : 6 mm T4-5-14 Pressure Gauge Pressure Check Port Adapter T4GB-04-05