hitachi — Overload Relief Valve Set Pressure

OPERATIONAL PERFORMANCE TEST / Component Test Overload Relief Valve Pressure Adjusting Procedure NOTE: In principle, adjust the overload relief valve pressure on a test stand. Adjust the pressure setting of the overload relief valve with adjusting screw (2) after loosening lock nut (1). 1. Loosen lock nut (1). 1 : 17 mm 2. Turn adjusting screw (2) and adjust the pressure. : 6 mm 3. Tighten lock nut (1). : 17 mm : 29.5 N m (3.0 kgf m, 22 lbf ft) W107-02-05-128 4. Check the set pressure. 2 Pressure Decrease Pressure Increase W107-02-05-129 T4-5-15 2 2 NOTE:

Standard Change in Pressure (Reference) Adjusting Screw Turns 1/4 1/2 3/4 1 Change in Pressure MPa (kgf/cm2) (psi) 5.2 (54) (770) 10.6 (108) (1540) 15.9 (162) (2300) 21.1 (216) (3070)