hitachi — Main Pump Flow Rate

OPERATIONAL PERFORMANCE TEST / Component Test MAIN PUMP FLOW RATE P-Q Control (Torque Control) Summary: Main pump performance is checked by measuring the pump flow rate by using a hydraulic tester installed at the main pump delivery port to be measured. Use Dr. ZX and a pressure gauge at the same time. IMPORTANT: This measurement procedure is a simple method. The measured data will be lower by approx. 5 % than the accurately measured value. In order to measure accurately, disconnect the return circuit from the control valve and connect it to the hydraulic oil tank. Preparation: 1. Stop the engine. Push the air bleed valve and release any remaining pressure.

Install a vacuum pump to the oil filler port. 5. Install a pressure gauge to the main pump. (Refer to the page on Main Pump Relief Pressure.) : 6 mm 6. Remove hose (11) from the regulator. Install plug (G1/4) to the hole on hose (11). : 17 mm 7. Remove the vacuum pump. Loosen plug (10) on top of the pump casing. Bleed air from the pump casing until oil only comes out of the plug clearance. 8. Fully open the loading valve of hydraulic tester. 9. Start the engine. Check for any oil leaks at the pressure gauge connection. Install Dr. ZX and select the monitor display function of MC. Measurement: 1. Maintain the hydraulic oil temperature at 50 ± 5 ° C (122 ± 41 ° F). 2.

Measure the maximum flow rate. 3. Set engine speed at fast idle. Depress the accelerator pedal fully. 4. Adjust the main relief valve set pressure in the control valve to each pressure point specified along the main pump P-Q curve. (Refer to T4-2.) Slowly close the loading valve of the hydraulic tester while relieving the pressure in the bucket crowd circuit. Measure the flow rates and engine speeds at the pressure points specified in the P-Q curve. 5. Repeat the measurement three times and calculate the average values. NOTE: Operate the vacuum pump while connecting the pump flow rate test line. 2. Remove the delivery hose from the main pump.

Install pipe (1) to split flange (8) in the removed hose with the bolt. : 41 mm : 10 mm 3. Connect pipe (1) to hydraulic tester (4) with test hose (2) and adapter (3). Install adapter (5), joint (6) and flange (7). : 41 mm : 10 mm 4. Connect flange (7) to the delivery hose with split flange (8) and bolt (9). : 10 mm T4-5-16