hitachi — Regulator Adjustment

OPERATIONAL PERFORMANCE TEST / Component Test REGULATOR ADJUSTMENT 1 2 7 8 9 10 T4GB-04-05-016 1 - Lock Nut (For Minimum Flow Rate) 4 - Adjusting Screw (For Maximum Flow Rate) 7 - Lock Nut (For P-Q Control) 9 - Lock Nut (For P-Q Control) 2 - Adjusting Screw (For Minimum Flow Rate) 5 - Lock Nut (For Pilot Pressure Characteristic) 8 - Adjusting Screw (For P-Q Control) 10 - Adjusting Screw (For P-Q Control) 3 - Lock Nut (For Maximum Flow Rate) 6 - Adjusting Screw (For Pilot Pressure Characteristic) T4-5-20 4 3 6 5 Adjustment Item Adjustment Procedure Remarks 1. Maximum Flow Rate ZW220 Loosen lock nut (5) and turn adjusting screw (6).

Rotate adjusting screw (6) 1/4 a turn clockwise and the maximum pump flow rate decreases by 11.26 cm3/rev. (0.69 in3/rev). : 32 mm : 40 N⋅m (4.1 kgf⋅m, 30 lbf⋅ft) ZW250 Loosen lock nut (3) and turn adjusting screw (4). Rotating adjusting screw (4) 1/4 a turn clockwise and maximum pump flow rate decreases by 12.58 cm3/rev. (0.77 in3/rev). : 22 mm : 20 N⋅m (2 kgf⋅m, 15 lbf⋅ft) 1) Do not turn adjusting screw (6) more than two turns. 2) Do not increase the maximum flow rate. In other words, do not turn adjusting screw (6) counterclockwise. 3) Secure tighten lock nut (5) after the adjustment. 1) Do not turn the adjusting screw (4) more than two turns. 2) Do not increase the maximum flow rate.

In other words, do not turn adjusting screw (4) counterclockwise. 3) Securely retighten lock nut (3) after the adjustment.