Page 5 - 44 Section 5 – Maintenance Procedures CFP83 Series Intake clearance: 0.30 mm [0.012 in] Exhaust clearance: 0.61 mm [0.024 in] Check/set valves with engine cold - below 60°C [140°F]. NOTE: The clearance is correct when some resistance is “felt” when the feeler gauge is slipped between the valve stem and the rocker lever. Locate top dead center for cylinder No. 1. Check/adjust the valves indicated for STEP A (I = intake; E = exhaust). After tightening the rocker lever locknut, check the valve clearance to make sure the valve clearance has not changed. Torque Value: 24 N•m [212 in-lb] CAUTION Be sure the engine timing pin is disengaged to prevent damage to the engine timing pin.
Mark vibration damper and rotate the crankshaft 360 degrees. Set the valves indicated for STEP B. After tightening the rocker lever locknut, check the valve clearance to make sure the valve clearance has not changed. Torque Value: 24 N•m [212 in-lb] Drawing No. 9777, Section 5, Rev. 02-07