Section 7 – Adjustment, Repair, and Replacement Page 7-23 CFP83 Series Coolant Heat Exchanger Removal/Installation (Cont) CAUTION When establishing raw water flow, ensure that the raw water pressure does not exceed 414 kPa (60 psig) at the heat exchanger. Adjust the pressure regulators as required. Slowly open the Raw Water Manifold Bypass Line Outlet Isolation Valve. Observe raw water flow through the heat exchanger. Adjust the bypass pressure regulator if required. Close the Raw Water Manifold Bypass Line Outlet Isolation Valve. CAUTION When establishing raw water flow, ensure that the raw water pressure does not exceed 414 kPa (60 psig) at the heat exchanger.
Adjust the pressure regulators as required. Slowly open the Raw Water Manifold Normal Line Outlet Isolation Valve. Observe raw water flow through the heat exchanger. Adjust the normal pressure regulator if required. NOTE : If temperature does not stabilize, stop the engine and refer to Coolant Temperature Above Normal or Coolant Temperature Below Normal (Engine Running) in Troubleshooting Section 12. Check that engine operating temperature stabilizes between about 82 and 93 o C [180 and 200 o F]. Check that no coolant hoses are collapsed. When temperature has stabilized, stop the engine. Ensure that repairs are completed satisfactorily. Drawing No. 9777, Section 7, Rev. 02-07